92,00 82,00

INFOSEC X2 TOUCH - 700 VA UPS - LINE INT
[TUPSX2T700FR]

INFOSEC X2 TOUCH - 700 VA UPS - LINE INT
INFOSEC X2 TOUCH - 700 VA UPS - LINE INTERACTIVE - OUTLET

DESCRIPTION
In the event of short or prolonged power cuts, the X2 LCD Touch′s batteries ensure that your connected hardware continues to be supplied with power for several minutes enabling applications to be closed and the PC to be turned off.
Technical information
General
Technology: Line Interactive with Automatic Voltage Regulation
Power: 700 VA
Power factor: 0,5
Schuko/FR protected UPS outlets: 2
IEC surge protected outlets / Protected UPS outlets: 1/3
Protection & filtering
Output form: Modified sinewave
Protection: Discharge/overcharge/overload
FR/SCHUKO models - Input protection: Breaker
IEC models - Input protection: Fuse
UNIVERSAL models - Input protection: Fuse
Physical characteristics
Dimensions D x W x H (mm): 300 x 101 x 142
Net weight (kg): 4,4
Input technical characteristics
Voltage: 220/230/240 VAC
Voltage range: 162-290 VAC
Frequency: 50/60 Hz (auto sensing)
Output technical characteristics
Voltage: 220/230/240 VAC
Automatic voltage regulation (battery mode): +-10%
Frequency: 50 or 60 Hz +- 1Hz
Crest ratio: 3:1
Output current (A): 3
Battery
Battery charger: Operates when UPS is connected to mains
Cold start (no mains): Yes
Battery type: 12V/7AH
Number: 1
Recharging voltage: 13.7 Vdc
Recharging time: 4 to 6 hours to 90% after complete discharge
Backup time: From 6 to 40 min. (depending on model and connected load)
Indicators
LCD Touch screen: Touch LCD: Input voltage, output voltage, battery capacity, load level and UPS status
Communication
Communication: USB port
Audible alarms
Battery mode: Sounding every 10 seconds
Low battery mode: Sounding every second
Overload: Sounding twice every second
Battery replacement: Sounding every 2 seconds
Fault: continuously sounding
Environment
Ideal environment: 0-40, 0-90% of relative humidity (without condensation)
Noise level: <40 dB
Norms & sales informations (FR/SCHUKO / IEC Models)
Standard: CE RoHS
(EMC) Electomagnetic Compatibility: EN62040-2:2006, EN61000-4-2:2009, EN61000-4-3:2006+A1:2008+A2:2010, EN61000-4-4:2004+A1:2010, EN61000-4-5:2006, EN61000-2-2:2002
Low voltage (safety): EN60950-1:2006+A11:2009+A1:2010+A12:2011, EN62040-1:2008
Connection:
2 Schuko/FR / Universal protected UPS outlets for 500 VA models
1 power integrated input cable
1 USB communication port